| Tegangan AC Nominal (50/60Hz) | UO/Un | 60V | 120V | 230V | 230V | 230V | 440V |
| Tegangan Operasi Kontinu Maksimum (AC)) | Uc | 75V | 150V | 275V | 320V | 385V | 440V |
| Arus Pelepasan Nominal (8/20μs) | In | 20KA | 20KA | 20KA | 20KA | 10KA | 10KA |
| Arus Pelepasan Maksimum (8/20μs) | Imaksimal | 50KA | 50KA | 50KA | 50KA | 50KA | 50KA |
| Arus Pelepasan Impuls (10/350μs) | Iimp | 12.5KA | 12.5KA | 12.5KA | 12.5KA | 10KA | 10KA |
| Energi Spesifik | W/R | 39kJ/Ω | 39kJ/Ω | 39kJ/Ω | 39kJ/Ω | 25kJ/Ω | 25kJ/Ω |
| Mengenakan biaya | Q | 6,25 As | 6,25 As | 6,25 As | 6,25 As | 5A | 5A |
| Tingkat Perlindungan Tegangan | Up | 700V | 1000V | 1500V | 1600V | 1800V | 2000V |
| Waktu Respons | tA | <25ns | |||||
| Sekring Cadangan (maks) | 315A/250A gG | ||||||
| Peringkat Arus Hubung Singkat (AC) | ISCCR | 25KA/50KA | |||||
| TOV Tahan 5 detik | UT | 114V | 180V | 335V | 335V | 335V | 580V |
| TOV 120 menit | UT | 180V | 230V | 440V | 440V | 440V | 765V |
| Mode | Menahan | Kegagalan Aman | Kegagalan Aman | Kegagalan Aman | Kegagalan Aman | Kegagalan Aman | |
| Jumlah Pelabuhans | 1 | ||||||
UL Listrik
| Tegangan Operasi Kontinu Maksimum (AC) | MCOV | 75V | 150V | 275V | 320V | 385V | 440V |
| Peringkat Perlindungan Tegangan | Wakil Presiden | 330V | 600V | 900V | 1200V | 1350V | 1500V |
| Arus Pelepasan Nominal (8/20μs) | I | 20KA | 20KA | 20KA | 20KA | 20KA | 20KA |
| Peringkat Arus Hubung Singkat (AC) | SCCR | 100KA | 200KA | 150KA | 150KA | 150KA | 200KA |
Mekanikal & Lingkungan
| Kisaran Suhu Operasional | Ta | -40 F hingga +158F[-40℃hingga +70℃I |
| Kelembaban Operasi yang Diizinkan | RH | 5%…95% |
| Tekanan atmosfer dan ketinggian | 80k Pa...106k Pa/-500m...2000m | |
| Torsi Sekrup Terminal | Mmax | 39,9 lbf-in [4,5 Nm] |
| Penampang Konduktor (maks) | 2AWG (Padat, Beruntai)/4AWG (Fleksibel) | |
| 35 mm²(Padat, Beruntai)/25 mm²(Fleksibel) | ||
| Pemasangan | Rel DIN 35 mm. EN 60715 | |
| Tingkat Perlindungan | IP 20 (terintegrasi) | |
| Bahan Perumahan | Termoplastik: Tingkat Pemadaman UL94V-0 | |
| Perlindungan Termal | Ya | |
| Status Operasi/Indikasi Kerusakan | Hijau oke/Merah cacat | |
| Kontak Jarak Jauh (RC) | Opsional | |
| Kapasitas Pengalihan RC | AC:250V/0.5A ABC:250V/0.1A A:125V/0.2A;75V/0.5A | |
| Penampang Konduktor RC (maks) | 16AWG (Padat)/1,5mm²Terjual) |
Informasi Pemesanan
| Memesan Kode | 75 | 150 | 275 | 320 | 385 |
| BY1-12.5-XXX/1 | 1207511 | 1215011 | 1227511 | 1232011 | 1238511 |
| BY1-12.5-XXX/1S (dengankontak jarak jauh) | 1207512 | 1215012 | 1227512 | 1232012 | 1238512 |
| BY1-12.5-XXX/0 (modul cadangan) | 1207501 | 1215001 | 1227501 | 1232001 | 1238501 |
Legenda
Jalur L
N Netral
PE Pelindung Tanah
Kontak Sinyal S Opsional
| BY1-12.5-XXX/1(S) | 75 | 150 | 275 | 320 | 385 | 440 |
| Dimensi Unit Tunggal DIN 43880 | 1 CTN | |||||
| Dimensi Kemasan (T×L×P) | [200×230×330 mm] | |||||
| Jumlah Pesanan Minimum | 64Satuan | |||||
| BY1-12.5-XXX/0 | 75 | 150 | 275 | 320 | 385 | 440 |
| Dimensi Unit Tunggal DIN 43880 | 1 CTN | |||||
| Dimensi Kemasan (T×L×P) | [200×230×330 mm] | |||||
| Jumlah Pesanan Minimum | 64Satuan | |||||